Filter Results By:

Products

Applications

Manufacturers

Showing results: 91 - 105 of 121 items found.

  • Industrial Serial GSM Modem

    ENVIROMUX-GSM-IND - Network Technologies Inc

    Sends SMS messages to a pager or cell phone when a sensor goes out of range of a configurable threshold. SIM card supporting SMS messaging required (not included). Ideal for harsh environments and high temperatures up to 149°F (65°C). GSM/GPRS/EDGE 850/900/1800/1900 MHz. AT command compatible. Dimensions: 3.58x2.28x0.87 in (91x58x22 mm). Operating temperature: -13 to 149°F (-25 to 65°C). Operating humidity: up to 95% non-condensing RH. Regulatory approvals: CE, C-Tick. Compatible with ENVIROMUX-SEMS-16(U).

  • K-Band Waveguide Gunn Oscillator Module

    FMWGN1001 - Fairview Microwave Inc.

    FMWGN1001 is a K Band Waveguide Gunn Oscillator with a Center Frequency of 24.125 GHz and a Tuning Range of +/- 1.0 GHz. The unit has a Phase Noise @ 100kHz Offset of -95 dBc/Hz typ and Frequency Stability of -0.4 MHz/°C max. The Gun Oscillator has an Output Power of 10 dBm min and Power Stability of -0.04 dB/°C max. The Waveguide Gun Oscillator uses a Bias Voltage of 5.0 Volts and a Bias Current of 200 mA and has a Waveguide Size of WR-42 with a UG-595/U Flange.

  • Low-Voltage Tester

    69127 - Klein Tools, Inc.

    Device for checking live 6-24V, AC or DC circuits.Tests for shorts in automotive and truck electrical systems, motor field coils, radio and low-voltage circuits, ground circuit of all lamps, wiring, fuses, etc.Bulb in handle glows when circuit is complete (bulb included).Pointed 3-3/4'' (95 mm) probe makes checking easier.Deluxe 3.5'' (89 mm) long handle with nylon top holds replaceable bulb.36'' (914 mm) test lead with alligator clip.Replacement bulb: Cat. No. 69130

  • Regulated Power Supplies, Output 0 to 24 VDC, 400 AMPS, 9.6 KW, P/N 5944C2

    Carl E. Holmes Company

    - Regulated Power Supply, 9.6 KW P/N 5944C2- Input: 220 VAC, 3 PH, 50/60 Hz- Output: 0 to 24 VDC, 400 Amps max- Duty factor: 100%- Ripple voltage: <3% across full output range- Setting: 0 – 100% current and voltage- Control: Constant current and voltage control- Ambient temperature: up to 95 degrees F- cooling: Forced air-cooled- Dimension: 17.6″H x 19.9″W x 21.6″D- Weight: 175 lbs.- Degree of protection: NEMA 2

  • Humidity/Temperature Datalogger

    Extech SD500 - Extech Instruments Corporation

    This Humidity/ Temperature Datalogger records data on an SD card in Excel format for easy transfer to a PC for analysis. It features a Dual LCD that simultaneously displays Relative Humidity and Temperature, and a selectable data sampling rate of 5, 10, 30, 60, 120, 300, and 600 seconds. Each stored reading includes a date and time stamp. 10 to 95% Relative Humidity and 32 to 122°F (0 to 50°C) Temperature ranges. Complete with 6 AAA batteries, SD memory card, Universal AC Adaptor, and mounting bracket.

  • ISA bus GPIB Controller Card

    Model 488-PC2 - ICS Electronics

    * Adds GPIB Controller capability to any PC with an ISA bus.* Fast data transfer rate, > 300kbytes per second.* Drivers for MS DOS, Windows 3.1, Windows 95 and Windows 98. * IEEE-488.2 linkable libraries for Quick Basic, MS Visual Basic, Borkand C/C++ andMicrosoft C/C++.* Functions as System Controller, Controller-in-charge or a GPIB Device.* Replaces most generic ISA 7210 Cards and NI PC2a cards.* Includes interactive keyboard Control Utility for controlling instruments from the computer keyboard without writing a program.

  • Walk-In Aging Chamber

    ACMAS Technologies Pvt. Ltd.

    Aging Chamber has been designed to simulate environmental condition to test the stability and reliability of products under stressed environment. Weiber is a leading manufacturer and supplier of Aging Test Chamber in India and abroad. Weiber offers scientific equipments at the most economical rates and versatile design. Microprocessor based Aging Test Chambers are made in accordance with the international testing standards. The equipments are NABL, NSF certified and CE approved. Aging Chamber maintains 25% to 95 % RH. The Test Chamber is digitally controlled delivering accurate result under controlled environmental conditions.

  • TLP Probe Arm Kit

    TPA-95 - High Power Pulse Instruments GmbH

    *Flexible pulse force, pulse sense combined TLP probe arm kit based on TPA-95L and TPA-95R*Compatible with typical standard micropositioner mechanical interfaces*4.7 kΩ pulse sense voltage divider, which results in a voltage transfer ratio of (4700 + 50)/50 = 95 : 1 into 50 Ω*Variable probe pitch configuration*1 m flexible 50 Ω cables with SMA connector for pulse sense*0.1 m flexible 50 Ω cables with SMA connector for pulse force*Tungsten probe tips*Can be used for chuck backside grounded TLP measurements

  • Intrinsically Safe In-line Hydrogen Process Analyzer

    HY-OPTIMA™ 1700 Series - H2scan Corp.

    H2scan’s HY-OPTIMA™ 1700 series in-line, real time hydrogen-specific process analyzers are designed for ease of use, interface flexibility and true process control. The HY-OPTIMA™ 1700 series is an ATEX certified Intrinsically Safe (IS) device that incorporates our patented solid-state sensor and is configured to operate in background gas streams with up to 95% relative humidity and temperatures up to 60ºC. The HY-OPTIMA™ 1700 series is ideal for process gas applications where real time continuous measurements of hydrogen can increase process plant efficiencies, improve diagnostics and enhance maintenance management translating into higher profitability.

  • Pressure Test & Calibration Pumps

    Additel Corporation

    Pressure Test Pump is a hand operated pressure pump designed to generate pressure from 95% vacuum to 1,500psi (100bar). A high-quality screw press is designed for fine pressure adjustment, with an adjustment resolution up to 10 Pa (0.1 mbar). A specially designed shut-off valve makes the pressure as stable as possible during calibration. A built-in gas-liquid isolator protects the pump from moisture and dirt to reduce the need for maintenance. Two hand-tight quick connectors installed on the pump allow easy connecting and disconnecting to the test pump without the need for PTFE tape or wrenches. The 918 is an ideal comparison test pump for pressure instruments calibration.

  • Wind Direction Sensor

    ENVIROMUX-EWDS - Network Technologies Inc

    Balanced wind direction vane with a near-zero friction bearing and a high accuracy magnetic angle sensor to provide precision wind direction. Sensor range: full 360 degrees , zero deadband. Accuracy: ±1.8 degrees. Resolution: 12 bit or 0.025 degrees. Directional Vane approximately 8 inches (203 millimeters). 3 wire flying leads, 25-feet (7.6-meter). Supply voltage: 4.5 to 5.5 VDC. Current: 15 mA typical. Output: 5 to 95% of input voltage (0.25 to 4.75VDC). Requires the ENVIROMUX-S5VDC-5V to operate with ENVIROMUX-2D/5D/16D. Maximum cable length: 1000 ft (305m)

  • Power ICs - VRPower® (DrMOS) - Power Stage

    Vishay Intertechnology, Inc.

    The Next Generation VRPower® Power Stage, Vishay’s family of VRPower modules offers an integrated MOSFET and driver power stage with unsurpassed performance. The flagship device, SiC620R is capable of 70 A and achieves more than 95 % efficiency in a typical multiphase buck converter design. The device has several package enhancements that enable it to offer superior MOSFET dynamic performance. Combined with Vishay’s state-of-the-art Gen IV MOSFET technology, these enhancements enable 3 % better efficiency and over 50 °C lower operating temperatures compared to previous generation DrMOS devices while shrinking the footprint by 33 %.

  • Reach-In Ageing Test Chambers

    ACMAS Technologies Pvt. Ltd.

    Aging Chamber has been designed to simulate environmental condition to test the stability and reliability of products under stressed environment. Weiber is a leading manufacturer and supplier of Aging Test Chamber in India and abroad. Weiber offers scientific equipments at the most economical rates and versatile design. Microprocessor based Aging Test Chambers are made in accordance with the international testing standards. The equipments are NABL, NSF certified and CE approved. Aging Chamber maintains 25% to 95 % RH. The Test Chamber is digitally controlled delivering accurate result under controlled environmental conditions. This chamber also known as Accelerated Ageing Test Chamber.

  • Damp-Heat Tester

    King Design Industrial Co., Ltd.

    1. Technical index:*Power: 380V, 3-, 50/60HZ 110A*Temperature range: 50°C~120°C*Humidity range: 20%~95% RH*Accuracy: 1) temperature ± 0.3°C;2) humidity ± 2.5% RH*Uniformity: 1) temperature ± 2.0°C;2) humidity ± 3.0% RH*Uniformity test: measured at T=85°C, RH=85%; set 9 points for temperature measurement and 2 points for humidity.*Inner wall is above 50 cm; within 20 min after temperature/humidity meets the setting value, the distribution uniformity of temperature/humidity can meet the aforesaid requirement.

  • Thermometer Hygrometer

    Model 302 - Rinch Industrial Co.,Limited

    1. Time,date display.2. Time alarm clock every day.3. 12/24 hours system clock.4. ℃/℉ temperature display.5. Relative humidity and comfort display.6. Temperature and relative humidity trend display.7. Max/Min Temperature and relative humidity display.8. Temperature measure range: -20℃~50℃9. Temperature resolution: 0.1℃10. Temperature accuracy: ±1℃11. Humidity measure range: 10%~95%RH12. Humidity resolution: 1%13. Humidity accuracy: ±5%RH14. Measuring period: 20 sec15. Power: 1.5V (AAA or 7# battery)